FLUXO RHT

FLUXO RHT

White Developer for Penetrant Testing
Form e according to EN ISO 3452
Suspension of inert white particle in a flammable volatile organic solvent.

Approval & Specifications

  • Processing Temperature : 50° to 200°C
  • NF EN ISO 3452-2 and NF EN 571-1
  • NF EN ISO 3452-5 (High temperature)
  • RCC-M Code
  • ASME BOILER AND PRESSURE VESSEL CODE, SECTION V
  • ASTM E 1417 - ASTM E 165
  • Low in Sulphur & Halogens (Nuclear Quality)

Application

  • Cleaning: Remove rust, tinder and all contaminations from the part with FLUXO cleaner
  • Application of Penetrant: Apply FLUXO PTH by spraying.
  • Removal: Remove the excess penetrant from the surface FLUXO NHT.
  • Developing: Apply FLUXO RHT developer on the part,achieving a thin and uniform layer.
  • Inspection: Parts shall be inspected as per ISO 3059 standard requirements. Surface defects will appear as red indication.